Please rotate your device

We don't support landscape mode yet. Please go back to landscape mode for
the best experience

Legend

Permeation breakthrough times - Minutes

Good Protection

> 480
240-480

Medium Protection

120-240
60-120

Splash Protection

30-60
10-30

Not Recommended

< 10

Degradation Ratings

  • E -Excellent
  • P -Poor
  • G -Good
  • NR - Not Recommended
  • F - Fair
  • DD -Delamination of outer layer

Chemicals Remove All

Product

CAS
Chemical Name
%
Thickness: 0.19 Material: Nitrile/Neoprene
93-260

Remove?

NO YES
Thickness: 0.12 Material: Nitrile
92-500.600.605 / 93-250.300.700

Remove?

NO YES
Thickness: N.A. Material: Nitrile
58-530.535

Remove?

NO YES
Thickness: 0.2 Material: Viton Butyl
38-612

Remove?

NO YES
Thickness: 0.35 Material: Butyl
38-514

Remove?

NO YES
Thickness: N.A. Material: PVA
15-554

Remove?

NO YES
Thickness: N.A. Material: Neoprene
08-352.354

Remove?

NO YES
Thickness: N.A. Material: PVC
04-414

Remove?

NO YES
Thickness: 0.062 Material: LLDPE
02-100

Remove?

NO YES
Disclaimer - Thank you for requesting a chemical guardian report for gloves. In this report, you will find information relating to the barrier performance of the gloves with the chemicals that you selected. The information may comprise of experimental data, or estimations based on extrapolations from experimental data. This information is intended to enable the Health and Safety professional at your organization to be able to make more informed decisions about which Ansell products will offer the greatest protection in the intended circumstances, and assist with carrying out a risk assessment for your organization.
We wish to highlight that the permeation times do not equate to safe wear time. Safe wear time may vary depending on whether or not the PPE is donned correctly, the temperature of the surroundings, the toxicity of the chemical, and a number of other factors. It is the responsibility of your organizations Health and Safety professional to undertake a risk assessment before choosing the appropriate PPE for the task at hand. If you would like to discuss any aspect in more detail, please contact us. Estimations of the barrier properties of gloves and PPE are based on extrapolations from laboratory test results and information regarding the composition of the chemicals. Synergistic effects of mixing chemicals have not been accounted for.
Estimations are subject to change if new testing is carried out providing better grounds for extrapolations. For these reasons, any information in this report must be advisory only and Ansell fully disclaims any liability including warranties related to any statement contained herein.